This process of examination is often performed at the time of sale of a house. Terry F. Brewer & Associates. Inspection Checklist - The checklist has four (4) columns; three of which are auto generatedby COMcheck : 1. Standard 90.1 requires that U-factors (and air leakage) for doors be determined in accordance with the NFRC rating procedures. H23U0t.=s#0ag C402.3.1 Maximum area. 0 0 0 rg The commercial building project shall comply with the requirements in Sections 502 (Building envelope requirements), 503 (Building mechanical systems), 504 (Service water heating) and 505 (Electrical power and lighting systems) in its entirety. One of the reasons for this change, is years ago shell buildings being built did not have to meet the building envelope provisions, however, the intent of these buildings is that later on the spaces would be leased out and most likely conditioned. endstream endobj 395 0 obj <>/Subtype/Form/Type/XObject>>stream NECB (10.2.2.3.) Since 2016, a COMcheck report has been required on all commercial plan reviews. Locate the lighting fixture library in this location defaulted by COMcheck: Copy fixtureLibrary.xml from this location to the same directory on the other computer. endstream endobj 355 0 obj <>/Subtype/Form/Type/XObject>>stream The COMcheck trade-off alternative used for enforcing the IECC is permitted under a clause in Section 101 (referencing 2012 IECC). ASHRAE 90.1-2010/90.1-2013 5.1.2.4. How can a COMcheck-Web or REScheck-Web project be shared with other team members? The ASHRAE Appendix C trade-off method does include a limited number of embedded references to ASHRAE 90.1 based prescriptive requirements that must be enforced. We provide plan review with ResCheck, IC3 or ComCheck Reports, onsite inspections for compliance with envelope inspections, insulation inspections, lighting and mechanical . Before submitting your building plans for review visit the Planning and Development Department, Subdivisions Section for a development plat review. Louvers are best treated as un-insulated portions of the wall. This includes above- andbelow-grade walls, between floor spandrels, peripheral edgesof floors, and foundation walls. Only 90.1-2013 uses this method currently although 2015 IECC does allow a project to apply 90.1-2013 in its entirety as an alternative. H23U0t.=s#0ag Purpose of Section 503: Access Agreement for Construction and Maintenance. After being a contractor for over 22 years, I felt there needed to be better communication between the RAS, Architect and the General Contractor. If other is selected, the user will then need to enter the overall calculated U-factor for the entire assembly and document those calculations to the building official. As a workaround, we recommend that you split your basement walls so that for eachbasement wall you add a new above-grade wall to represent the above-grade area of thebasement wall. Otherwise, only the more recently used projects are listed. Residential construction. One copy of structural calculations sealed by engineer of record Structural special inspection certificate Per the requirements of Senate Bill 1598, this permit application is: . (depending upon the assembly). To share a particular project with others on COMcheck-Web or REScheck-Web, you have a couple options: Note: if you have many projects already loaded in your account you might need to click All at the top of the My Projects window to see all the projects. hbbd```b``+@$#,D2,`5>qF8s`808~|&azLjHxgfk I6pz`T 2! REScheck works by performing a simple U-factor x Area (UA) calculation for each building assembly to determine the overall UA of a building. This list contains greater de tail as to what is submitted with a building permit package. Download a copy of the presentation slides and watch the recording of the workshop: For questions, please contact Commercial Plan Review, 832.394.8810 or email [emailprotected]. H23U0t.=s#0ag COMcheck Desktop for Windows may be downloaded and installed directly to your desktop. Letter of utility availability for water, waste water and storm drainage. The file is saved but I cannot get a pdf or rtf file to print. endstream endobj 339 0 obj <>/Subtype/Form/Type/XObject>>stream endstream endobj 326 0 obj <>/Subtype/Form/Type/XObject>>stream Announcements. 0 0 0 rg Services. In ASHRAE 90.1-2010 and -2013, buildings being constructed must be assumed to be conditioned. Cavity insulation is used within the wood- or metal-framed wall, while rigid continuous insulation (c.i.) 843 0 obj <>stream You can do your home inspection; however, it should not stand in place of a professional inspection. (on center) and cavity wall insulation R-values greater than R-15 are modeled as 2x6 studs at either 16 or 24 O.C. This is only a general list and is not . endstream endobj 332 0 obj <>/Subtype/Form/Type/XObject>>stream NOTE: Once these weather files are downloaded they will remain on the PC at C:\ProgramData\COMcheck\eplus\weather. %R@PBL1X Kh endstream endobj 364 0 obj <>/Subtype/Form/Type/XObject>>stream H23U0t.=s#0ag These are sample forms and many of them may be modified to accommodate your companys needs. hZ{6*3]LQ$EP,]\d7k]h[,zq?c`!g7d`!mDD= ZF}0pva2)IRHE:4!~Dg#\0 >!t9C)GIHHc %JE!/s0ra`0ed(i0mPZ'!. 0 0 0 rg Jeff Gutknecht is committed to providing a better style of performing the TDLR (Texas Department of Licensing and Regulation) PLAN REVIEWS. To help the development community adjust to the new procedure, Building Code Enforcement hosted an online workshop to explain the: A newCOMcheck guidelinewas developed to help the development community avoid frequently missed items. Search: TFBA.COM specific applicable inspections prior to obtaining a Certificate of Occupancy. COMcheck, or equivalent IECC energy compliance documentation . 0 0 0 rg USA_NJ_Newark.Intl.AP.725020_TMY3.epw (~1,619 KB), USA_NJ_Newark.Intl.AP.725020_TMY3.ddy (~29 KB). Independent controls for each space (switch/occupancy . COMcheck Desktop for Windows may be downloaded and installed directly to your desktop. (b) semiheated space: an enclosed space within a building that is heated by a heating system whose output capacity is greater than or equal to 3.4 Btu/h*ft2 of floor area but is not a conditioned space. Where special conditions exist, the code official is authorized to require necessary construction documents to be prepared by a registered design professional. Therefore, the weather download process only needs to execute one time per unique project location. Follow the step-by-step instructions below to design your john deere tractor inspection checklist: Select the document you want to sign and click Upload. To receive updates from the Building Energy Codes Program, including newsletters, articles, compliance tool updates and more, subscribe to the BECP mailing list. 90 North William Dillard Drive suite C-109, Gilbert. %R H23U0t.=s#0ag %R Once the user enters the proposed insulation R-value(s) for the assembly, the program recalculates the assembly and updates the U-factor to the overall U-factor for the entire assembly. hb```g`` B@16&lO4^Y&y5@E& i To obtain a permit the following documentation is required (but not limited to): Download the Commercial Plan Review Prerequisiteschecklist. endstream endobj 398 0 obj <>stream assigned the default values in Section A7.1. %R@PBL1X Kh H23U0t.=s#0ag COMcheck is the U.S. Department of Energy (DOE)'s commercial energy compliance tool that essentially tells a user whether or not a building meets the requirements of the International Energy Conservation Code (IECC) and ASHRAE 90.1, as well as state-specific codes.. Has a peak design rate of energy usage less than3.4 Btu/h * ft, Those that do not contain conditioned space, the files are not located at this default location, only one file is there instead of the two needed. 1.68 1.68 6.6 6.6 re endstream endobj 353 0 obj <>/Subtype/Form/Type/XObject>>stream H23U0t.=s#0ag Respond to complaints regarding many code violations. Note: There is an allowance for up to 1% of wall area in recessed equipment in walls in Standard 90.1 if 90.1 is the code in which you are complying with. endstream endobj 344 0 obj <>/Subtype/Form/Type/XObject>>stream (D) COMcheck versions. When using the ASHRAE 90.1-2013 energy code, COMcheck needs to have two EnergyPlus weather files in this folder C:\ProgramData\COMcheck\eplus\weather. Insulation that runs continuously over structural members and is free of significant thermal bridging; such as rigid foam insulation above the ceiling deck. This type of system will enforce the system efficiency depending on the system cooling capacity. %R@PBL1X Kh endstream endobj 393 0 obj <>/Subtype/Form/Type/XObject>>stream Inadequate checks and poor training can lead to serious electrical injuries and fatalities. Inspect higher-risk properties for compliance with fire codes. (Pick up application on the 1st floor). Consider your work environment. endstream endobj 349 0 obj <>/Subtype/Form/Type/XObject>>stream %R@PBL1X Kh The following is the code section that enforces this: C406.2 Efficient HVAC performance. Does energy code compliance need to be shown for a warehouse? View a list of supported software versions for code compliance tools. Ryan's attention to detail and . OSHA 1910.178 (q) (7) requires daily pre-shift forklift inspections for safety compliance. This default value gives credit for some minimal type of sheathing material (such as plywood) under the siding. endstream endobj 367 0 obj <>/Subtype/Form/Type/XObject>>stream endstream endobj 340 0 obj <>/Subtype/Form/Type/XObject>>stream You may contact Planning at 832.394.8849 and Taps & Meters at 832.394.8888 for more information. Note: REScheck Desktop only supports compliance through the 2015 IECC. How does COMcheck calculate percentage of glazing? See if your state or county can use COM check to show compliance. This permit is issued when an additional structural permit is required for a structure. Upon application for a new home' s Certificate of Occupancy , the program's verification summary (i.e. The term residential building includes: Exterior walls in REScheck are defined by the assembly type, gross wall area, cavity/continuous Rvalue (U-factor for Other walls) and orientation. H23U0t.=s#0ag COMcheck-Web - 2009 IECC Code/Location Code: State: City: If your location is not included here, choose a nearby location with similar weather conditions. Also, the air leakage rates changed. One option is to share the log in credentials with them and save all edits to the project under that account. Both RES check and COM check are available free of charge. REScheck uses nominal insulation R-values. endstream endobj 354 0 obj <>/Subtype/Form/Type/XObject>>stream Thermal bridges: can these bridges include interruptions in . Can you combine two data files into one project? There are three variants; a typed, drawn or uploaded signature. Next is the applicable energy code. Benefits of COMcheck submittals for code officials Helps designers verify all requirements are met prior to submittal Helps ensure comprehensive documentation of energy code requirements Facilitates faster plan reviews Assists inspectors onsite with auto-generated inspection . This code is intended to provide flexibility to permit the use of innovative approaches and techniques to achieve this objective." 2023. When continuous foam insulation is specified, 100% of the wall is assumed to be covered at the specified R-value. endstream endobj 342 0 obj <>/Subtype/Form/Type/XObject>>stream "LR@PBPBLM, k Help Desk inquiries submitted during this time will be answered the first week of January. During Tree Inspection. endstream endobj 397 0 obj <>/Subtype/Form/Type/XObject>>stream f %R Show. Q6. REScheck Desktop for Windows may be downloaded and installed directly to your desktop. Q 5: What do I need to have, for a Commercial Inspections? Brochure for Building Plan Review and Inspection Under Wisconsin's Commercial Building and Heating Codes . endstream endobj 358 0 obj <>/Subtype/Form/Type/XObject>>stream Checklist Inspections. Required Compliance Forms ALEA Motor Carrier Safety Unit The following forms will assist you in completing your company files. 5.5, Prescriptive Building Envelope Option, provided that. Check with the building official where the project is located to confirm the city selected will be acceptable or if choosing county as the designation would be more appropriate. The 2009/2012 editions of the IECC (commercial provisions) do not include language explicitly describing a defined envelope trade-off compliance method. Data filename: S:\2014\Jobs\014-013 DCG-Vehicle Maintenance Facility Expansion\Calcs\HVAC\COMcheck\DCG Mechanical COMchedk.cck Page 1 of 2 COMcheck Software Version 3.9.4 Mechanical Compliance Certificate 2012 IECC . This process is done in conjunction with other related trades with the Mecklenburg County Land Use and Environmental Services Agency (LUESA). The Best Forklift Inspection Checklists - with Free Templates. This code shall regulate the design and construction of buildings for the effective use and conservation of energy over the useful life of each building. When applied to the IECC energy codes, all IECC code requirements are applied and enforced within that trade-off methodology when a clear and obvious reference can be established. How does the importing of a gbxml file option function? Department of Building Inspection 9800 Government Center Pkwy P.O. endstream endobj 396 0 obj <>/Subtype/Form/Type/XObject>>stream 1.68 1.68 6.6 6.6 re JU ];yNw`syX}kwN>7[y:N1Z'mz3YouI]6S`~n;t $@ 0I_{Xl~zDeFZ)y7kMJ+cuJk+g`0F,=OsWmR6Iv::F)#Z^?KQE#y\-"D GvUuz{DmDQO .y#O0esVd]D'aCbigB:MU. %R@PBL1X Kh D -APPLICATION FOR EMPLOYMENTPDF/13mb |49 CFR 391.21 |NEW EMP, D -INQUIRY TO PREVIOUS EMPLOYERSPDF/2mb |49 CFR 391.23(a) (2) & (c) |3YRS, D -INQUIRY TO STATE AGENCIES |49 CFR 391.23(a) (1) & (b) |3YRS, D -ANNUAL REVIEW OF DRIVING RECORD |49 CFR 391.25 |1YR, D -ANNUAL DRIVERS CERTIFICATION OF VIOLATIONS |49 CFR 391.27 |1YR, D -DRIVERS ROAD TEST CERTIFICATE OR EQUIVALENT |49 CFR 391.31 |NEW EMP, O -HRS OF SERVICE FORM/ FIRST OR INTERMITTENT DRIVERS |49 CFR 395.8(j) (2) |AS NEEDED, D -DRIVERS DAILY LOG |49 CFR 395.8 |DAILY, O -SUMMARY OF HOURS WORKED AND HOURS AVAILABLE |OPTIONAL DAILY, O -DRIVER OFF DUTY LETTER FOR LUNCH OR BREAK |49 CFR 395.3 (GUIDANCE Q.9) |AS NEEDED, O -DRIVERS TIME RECORD (100 OR 150 MILES EXEMPTIONS) |49 CFR 395.1(e) |DAILY, V -DRIVERS VEHICLE INSPECTION REPORT |49 CFR 396.11 |DAILY, V -VEHICLE SERVICE DUE STATUS REPORT |49 CFR 396.3 |AS NEEDED, V -INSPECTION, REPAIR & MAINTAINCE RECORD |49 CFR 396.3 |AS NEEDED, O -MULTIPLE EMPLOYER DRIVER CHECKLIST |49 CFR 390.5 |NEW EMP. U-factor assembly calculations are taken from ASHRAE Appendix A and ASHRAE Fundamentals. 1.68 1.68 6.6 6.6 re Plan Review. Submit plans electronicallythrough ProjectDoxincluding (but not limited to): Electrical (added loads, line diagrams, load analysis), Health equipment details with plan of elevation (food establishments only), Inspection checklist which follows the compliance certificates. responsibilities of review for DSD staff. %R Working with that manyenvelope components in COMcheck is unreasonable, which is why we identify surfaceswith similar characteristics and aggregate them during the import process. Building Energy Codes Program is a resource of the U.S. Department of Energy's Building Technologies Office. Whether you go to the factory yourself to check the quality of your products or hire a third-party QC company to do so, the checklist tells the inspector what to look for. endstream endobj 388 0 obj <>/Subtype/Form/Type/XObject>>stream Where the COMcheck report states "alteration" as the project type. H23U0t.=s#0ag below-grade wall: that portion of a wall in the buildingenvelope that is entirely below the finish grade and incontact with the ground. f The program does not calculate for compression. %R The Uofactor for all frame walls is based on the Rvalue of cavity insulation and the continuous insulation Rvalue (if used). /Tx BMC H23U0t.=s#0ag 472 0 obj <>stream ASHRAE's definitions for these types: space: an enclosed space within a building. H23U0t.=s#0ag endstream endobj 346 0 obj <>/Subtype/Form/Type/XObject>>stream H23U0t.=s#0ag endstream endobj 351 0 obj <>/Subtype/Form/Type/XObject>>stream The classifications . Insulated sheathing installed on the exterior of above-grade walls is an example of continuous insulation. 2. %R@PBL1X Kh The following is a general outline of drawings necessary for plan review (Building Permits and Inspections Division may request additional information if necessary). This means you will stillbe required to manually specify your space types, lighting fixtures, and mechanicalsystems that appear in your building. View New! For structural insulated panels and insulated concrete forms, enter the manufacturer-reported R-value for the entire assembly. endstream endobj 360 0 obj <>/Subtype/Form/Type/XObject>>stream Insulation installed between structural members such as wood studs, metal framing, and Z-clips. The U.S. Department of Energy (DOE) is directed to provide technical assistance to states to support the implementation of model residential and commercial building energy codes (42 USC 6833). ENERGY EFFICIENCY AND RENEWABLE ENERGY, Forrestal Building REScheck-Web is accessible directly from the website without having to download and install. %R COMcheck can be used for commercial buildings or high-rise (>3 stories) multi-family buildings. Because your team completes these inspections every single day, it's easy to become complacent and start going through the motions. COMcheck Complaints against Construction Officials Complaints against Housing Inspectors Complaints against Landlords Complaints against Local Code Officials Complaints against Private Warranty Plans Compliance, Hotels & Multiple Dwellings Concrete Testing, 09-16-09 Condominiums -Associations Condominiums, Conversion Information 1.68 1.68 6.6 6.6 re H23U0t.=s#0ag Additionally, a bond is required for sidewalk/culvert/driveway permits. 0 %R Application for Modification of Sidewalks Standards. H23U0t.=s#0ag Alternative Plans Review and Inspection Forms. wall: that portion of the building envelope, including opaquearea and fenestration, that is vertical or tilted at an angle of 60degrees from horizontal or greater. endstream endobj 384 0 obj <>/Subtype/Form/Type/XObject>>stream Fire & Emergency. If that doesnt work, use the web tool which requires no download but you will want to register so you can save your projects. COMcheck is a nationally recognized software program to show compliance for International Energy Code Compliance for commercial building projects. COM check is the U.S. Department of Energy (DOE)'s commercial energy compliance tool that essentially tells a user whether or not a building meets the requirements of the International Energy Conservation Code (IECC) and ASHRAE 90.1, as well as state-specific codes. Please review the user guide for step-by-step instructions or watch our how-to videos: See our flowchart of astandard Commercial Plan Review process. endstream endobj 370 0 obj <>/Subtype/Form/Type/XObject>>stream 0 0 0 rg Table: Checklist for Visual Inspection of Concrete Structure. The embedded Appendix C requirements discussed in the previous paragraph pertain to maximum window (WWR) and skylight (SRR) areas and minimum skylight area. 0 0 0 rg f When entering doors in COMcheck, do I use "operable U-factor" or "caclulated U-factor? You can add them as a separate wall type (for example, if they are metal, metal building would probably be most appropriate) with no insulation but a wall area. COMcheck or equivalent program to verify compliance with 2018 Virginia Energy . Depending on the size of your building, a gbXML file can potentially containthousands of surfaces to fully represent your structure. Additionally, it is advised that you visit the Taps & Meters Section to ensure there is available water and wastewater for your project. requirements of the current Indiana Energy Conservation Code (675 IAC 19-4) (COMcheck reports must be run with current software, must show passing performance and must include the accompanying Inspection Checklist Report, which must report a score of no less than 100%); To receive updates from the Building Energy Codes Program, including newsletters, articles, compliance tool updates and more, subscribe to the our mailing list. For this reason, and that it is only the trade-off method that is being borrowed for use with the IECC requirements, these Appendix C embedded requirements are not considered when this method is applied to the IECC codes in COMcheck. These are part of the routine checkup when you bring your car to an inspector. Download our free printable Home Inspection Checklist. Simply click on ultimate home inspection checklist below to get your downloadable guide: Foundation, Structure, and Exterior The basis of any house inspection checklist comes down to getting the foundation and structure properly assessed. The U.S. Department of Energy (DOE) is directed to provide technical assistance to states to support the implementation of model residential and commercial building energy codes (42 USC 6833). %R Commercial, Compliance, COMcheck ASHRAE's space conditioning types include: conditioned space, unconditioned or semi-heated space. endstream endobj 375 0 obj <>/Subtype/Form/Type/XObject>>stream %R@PBL1X Kh endstream endobj 391 0 obj <>/Subtype/Form/Type/XObject>>stream Mechanics must be certified to perform Annual Vehicle Inspections. /Tx BMC See also Appendix E of the HBC. ASHRAE 90.1-2013 Appendix C supports a trade-off method that is based on building performance simulations using EnergyPlus completely differently than earlier versions of the 90.1 code family. H23U0t.=s#0ag %%EOF 2022 New York City General Administrative Provisions for Construction Codes. Plan Review (summarizing the Energy Code Provision) 3. Within COMcheck, a user is required to . Things to look out for while performing the tree inspection: Snapped, dangling, dried up or cracked branches. The other 20% is assumed to be covered with plywood. English. ", Why do I get an error when I click on "Check Compliance?". As such, the Louisiana State Uniform Construction Code Council (LSUCCC) has adopted the 2015 editions of the I-codes. Beginning January 1, 2021, plans submitted with incomplete COMcheck reports will be rejected at pre-screen. %R How is Cavity and Continuous Wall Insulation Calculated in REScheck? 2. The various compliance paths of the code are alternative "recipes" designed to achieve that intent, but Section 101 implies that other recipes are permitted if they accomplish the same overall objective. %R Review input and edit as necessary.. H23U0t.=s#0ag The requirements contained in this chapter are applicable to commercial buildings, or portions of commercial buildings. House inspection is an all-inclusive and comprehensive form of examination of a home using a house inspection checklist. endstream endobj 347 0 obj <>/Subtype/Form/Type/XObject>>stream Help Desk inquiries submitted during this time will be answered the first week of January. If you select this as your system the capacity of individual units will generally be so small that the economizer requirement will not be enforced. 0 Project Type New Construction Addition Alterations Project Details (optional) Edit Project Details This information will appear on the compliance report. Name, location, type, and size. Download via the link at the bottom of the right sidebar. 1.68 1.68 6.6 6.6 re endstream endobj 385 0 obj <>/Subtype/Form/Type/XObject>>stream Step 1: Choose a Checklist Template Firstly, choose a template that you think is the perfect fit for the kind of checklist you are creating. Specifically, Section 101 allows a building official to approve compliance tools that are deemed to meet "the intent of [the] code." The intent of the IECC commercial code is explicitly defined here: "C101.3 Intent. These are sample forms and many of them may be modified to accommodate your company's needs. If you are concerned about others having access to your personal account you can set up an independent account (using a unique email from your own present account) and create or upload the project to that new "shared" account. A: No appointment needed. The Scope and Application sections of the 2009 IECC address use of ASHRAE 90.1 (2007) as an alternative. The following forms will assist you in completing your company files. Building Energy Codes Program is a resource of the U.S. Department of Energy's Building Technologies Office. The insulating values of other parts of the building assembly (e.g., gypsum board and air films) are accounted for by the program and should not be included. 2022 New York City Plumbing Code. f endstream endobj 338 0 obj <>/Subtype/Form/Type/XObject>>stream Show more How does COMcheck calculate percentage of glazing? %R@PBL1X Kh The Energy Analysis must represent the entire project, including a building's envelope, HVAC, service water heating, lighting . These tools help simplify and clarify compliance with model energy codes, and are used by thousands of builders, designers, architects, and contractors each year. EMC endstream endobj 368 0 obj <>/Subtype/Form/Type/XObject>>stream Note: The key point is not the age of the building, but whether it is registered or eligible to be registered and listed. requirements of the current Indiana Energy Conservation Code (675 IAC 19-4) (COMcheck reports must be run with current software, must show passing performance and must include the accompanying Inspection Checklist Report, which must report a score of no less than 100%); ""Ae/g3060 pLv Inspections presuming to give authority to violate or cancel the provisions of this code or of other ordinances of the jurisdiction shall not be valid. endstream endobj 381 0 obj <>/Subtype/Form/Type/XObject>>stream This page contains the necessary forms and applications needed to apply for various permits and licenses. 1.68 1.68 6.6 6.6 re (Click here for more information.) Part III lists the responsibilities of review for the designer and licensed design professionals and . Section # & Req. To be effective, a checklist needs to be specific to the type of . endstream endobj 336 0 obj <>/Subtype/Form/Type/XObject>>stream They represent very poorly performing doors, which can be an issue for some buildings if the door area is a significant fraction of the wall area. Also users have the option to choose "other" as the assembly type. In COMcheck 4.0.0.3 and newer, you can now break up your VRF into two systems. COMcheck is a nationally recognized software program to show compliance for International Energy Code Compliance for commercial building projects. A plumbing permit is required forCommercial dryer installation. COMcheck input for uninsulated balconies on page BE-11 of the Supporting Documents How-To Guide. (c) unconditioned space: an enclosed space within a building that is not a conditioned space or a semiheated space. f Inspections for this program are handled by Home Ener gy Rating company, except that Section R403, entitled "Systems," of the 2015 IECC must be verified by the local construction of fice. 1. cooled space: an enclosed space within a building that is cooled by acooling system whose sensible output capacity exceeds 5 Btu/h*ft2 of floor area. CODE COMPLIANCE REVIEW CHECKLIST Design and Construction an iso 9001:20 15 certified organization Division of Codes and Construction Permitting, 34th Floor, Corning Tower The Governor Nelson A. Rockefeller Empire State Plaza Albany, New York 12242 Phone: (518) 474-0331 Design and Construction an iso 9001:20 15 certified organization Energy Code Compliance Inspections. An inspection checklist serves as a guide for the person inspecting your products during a product quality inspection. with an opinion or certification that the property is eligible to be listed on the National or State Registers of Historic Places either individually or as a contributing building to a historic district by the State Historic Preservation Officer or the Keeper of the National Register of Historic Places. When guidelines are not provided by the trade-off method language or refers to nonexistent section numbers, the IECC requirement will be enforced prescriptively. %R@PBL1X Kh More specifically, this applies to the table references to individual envelope assemblies U-factor requirements. Consequently, for compliance with Standard 90.1, door U-factors must be: Both the NFRC 100 and the Section A7.1 values are for the overall door area, including the door slab and the door frame. Technical Support Document for Version 3.9.1 of the COMcheck Software. Further, using this checklist does not guarantee or equate to compliance with the regulations. A DIY home inspection checklist can help you examine homes to purchase during the buying process's preliminary phases.